By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service. The dark mode beta is finally here. Change your preferences any time. Stack Overflow for Teams is a private, secure spot for you and your coworkers to find and share information. I've been digging quite a bit into IPMItool commands and have yet to find a comprehensive list of raw hex commands.

Our Dell rep tells me this isn't possible and that I'll have to pull up the web interface for all 90 machines and set this by hand. They also told me it wasn't possible to set the inlet temperature thresholds with IPMItool and I did that so my faith in Dell is dwindling. What little I've been able to find on the internet it looks like I might be able to make it happen with raw hex commands. Can anyone in the great internet wild help me? I ended up using the freeipmi tools ipmi-sensors-config and ipmi-pef-config.

First I ran ipmi-sensors-config -L grep Inlet to find which sensor number corresponded to the inlet temp for my C II machines it was sensor 16, but for my Cs it wasor sometimes 10, so be sure to do this. This sets the temps to what you want, but we're not done.

We have to actually have to set an event to react to these. Event 4 and 5 in my system corresponds to Temp Non-Critical and Temp Critical events for all temp sensors. Learn more. Asked 2 years, 7 months ago. Active 2 years, 7 months ago. Viewed times. Nick Nick 5 1 1 bronze badge. Active Oldest Votes.

Sign up or log in Sign up using Google. Sign up using Facebook. Sign up using Email and Password. Post as a guest Name.

ipmitool sel hex

Email Required, but never shown. The Overflow Blog. Socializing with co-workers while social distancing. Podcast Programming tutorials can be a real drag. Featured on Meta. Community and Moderator guidelines for escalating issues via new response…. Feedback on Q2 Community Roadmap. Technical site integration observational experiment live on Stack Overflow.

ipmitool sel hex

Triage needs to be fixed urgently, and users need to be notified upon…. Dark Mode Beta - help us root out low-contrast and un-converted bits. Related Hot Network Questions. Question feed. Stack Overflow works best with JavaScript enabled.You can use your system BMC to monitor your system vital signs.

For illustration purposes, focus on CPU temperature readings. In the IPMI 2. The first column is the sensorid name. This name is used to reference the sensor in other commands also.

The sensor reading in the second column indicates a healthy system. The last column displays the reading relative to threshold values. You can run a command by using the sensorid name CPU 1 Temp in this example.

When the sensorid name contains blanks, it must be surrounded by double quotation marks. The following command lists all the possible states of the CPU 1 temperature sensor:. You can confirm that the event is logged with the SEL command viewing he last event entry:.

The first column is a unique record number in the hexadecimal format. The next two columns are the date and time stamp. The fourth column shows the corresponding sensor.

The final column shows a description. Also, you can check whether your system had a possible bad health event by viewing the entire history of your System Event Log:.

The ipmievd daemon is related to the SEL. For more information about the ipmievd daemon, see the ipmievd man page. To see all available SDRs in your system, run the following command: ipmitool sdr list For illustration purposes, focus on CPU temperature readings. Also, you can check whether your system had a possible bad health event by viewing the entire history of your System Event Log: ipmitool sel list The ipmievd daemon is related to the SEL.GitHub is home to over 40 million developers working together to host and review code, manage projects, and build software together.

Skip to content. Permalink Dismiss Join GitHub today GitHub is home to over 40 million developers working together to host and review code, manage projects, and build software together. Sign up. Branch: master. Find file Copy path. Cannot retrieve contributors at this time. Raw Blame History. The platform lack the required kernel support.

Support for virtual mac is also implemented. The Sensor type supporting this are 0x0C and 0x This resolves issue where activation seems to have failed because ipmitool received an unsupported completion code. If completion code is C3, wait till timeout has expired before reporting it.

Password is limited to 16 bytes, resp. User name is limited to 16 bytes, no interface limitations. Useful for OEM sensor type. Adds proper umask before writing PID file.

Speed up transfer version 1. Removed "isol setup" command. You signed in with another tab or window. Reload to refresh your session. You signed out in another tab or window. The platform lack. Fixes reversed IPMIv1. ID Dell servers. This includes the support for 12G.

It is now possible to edit field 0 of sections. This resolves issue. If completion code.You seem to have CSS turned off. Please don't fill out this field.

UPDATE (2015-02-18)

Please provide the ad click URL, if possible:. Help Create Join Login. Operations Management. IT Management. Project Management. Services Business VoIP. Resources Blog Articles Deals. Menu Help Create Join Login. IPMItool Brought to you by: audetjmblaismcarolhferlandmand 5 others. Oh no!

ievents(8) - Linux man page

Some styles failed to load. Sign Up No, Thank you. Thanks for helping keep SourceForge clean. X You seem to have CSS turned off. Briefly describe the problem required :.

Upload screenshot of ad required :. I have few questions on this: a. Is it only for OEM specific event log messages and what happens if sdr table is built and used to decipher these messages.

What is the generic format of this file? Thanks, Manjunath A. As an aside Some time ago, I spent some time deciphering that SEL map file sorry can't remember the format.By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service. The dark mode beta is finally here. Change your preferences any time. Stack Overflow for Teams is a private, secure spot for you and your coworkers to find and share information. Learn more. Questions tagged [ipmitool].

Ask Question. Learn more… Top users Synonyms. Filter by. Sorted by. Tagged with. Apply filter. I was looking all over how to write such script but haven't found one yet. My main goal is from a Linux machine to Liri Elgozi 11 2 2 bronze badges. Strictly for monitoring purposes? Deal with low latency on ipmitool commands I am trying to work around the very high latency that I get when trying to execute some ipmitool commands on the OppenPower machine that I am connected to via ssh and on which the OpenIPMI tool is I just installed Cygwin and have been trying to follow the steps for building ipmitool 1.

Ray 1 1 bronze badge. How to set a python-ipmi target correctly? The idea is to have a shell session just like when Lucas Rebello 11 1 1 bronze badge. Why will ipmitool sometimes fail?

I have a number of servers that I regularly scan with ipmitool - that is, I run: timeout 5 ipmitool -I lanplus -H some.I have read the PowerEdge C System management document which recommends parsing the output of "ipmitool sel list", but would prefer to have the RAC send traps some errors may not allow access to the operating system. I understand that it will only send a generic trap out, but this will be fine.

I see that according to Dell's bmc book, PEF alerting is supported but cannot seem to get them alerting properly with ipmitool's event command. Has anyone done this previously who is able to offer any tips? Go to Solution. Ok, I have figured it out finally.

For future reference, the issue I was running into was attempting to change the existing pre-configured PEF table items. Create a new pef file with the correct alerting rules, destinations, community string etc.

View solution in original post. IPMI does not function over a normal remote connection on our cloud servers. The SNMP traps would need to go to an agent installed within the operating system of the server via IPMI, and from there be reported to a remote management station.

This document outlines the remote monitoring functionality on page 2, and provides suggestions for agents to use:. Thank you for the quick reply. It seems that the web interface does include a configuration that allows one to set SNMP trap destinations, alerting rules, etc The instructions involve running a few raw commands once the trap dest has been set:.

Do you happen to know of any additional documentation on this configuration? I have found some additional tools at poweredgec. Browse Community. Turn on suggestions.

Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. Showing results for.

ipmitool sel hex

Search instead for. Did you mean:. Event to send event: ipmitool -H xx. All forum topics Previous Topic Next Topic. Accepted Solutions. Hi Daniel, Thank you for the quick reply.

The instructions involve running a few raw commands once the trap dest has been set: After setting the SNMP Trap, you need do following steps to let trap alert: 1.By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service.

Questions tagged [ipmitool]

Server Fault is a question and answer site for system and network administrators. It only takes a minute to sign up. So, I use the raw command:. I've googled for several days, but can not find any information, and I've downloaded the source code of ipmitool, maybe I'll try to read the source code more clearly. My Question is, what is the netfn code should I use, and what is the command to get the Board Serial, is this case, the value should be GG3P Here raises another question: How to get raw command clues from the output of sudo ipmitool fru -vvv?

Sign up to join this community. The best answers are voted up and rise to the top. Home Questions Tags Users Unanswered. Asked 2 years, 11 months ago.

ipmitool sel hex

Active 2 years ago. Viewed 10k times. Any advice? Thanks in advance. I don't think you can use raw to extract this information. But anyway, could you edit the output of sudo ipmitool fru -vvv? Also: you can try your luck with this document: intel. Lenniey, thanks for your quick response, I've added the output of ipmitool fru -vvv in my question. Lenniey, I've added the result to the end of the context, but I have another question: How to get the raw command clues from the output of sudo ipmitool fru -vvv?

Not really need the Board Serial field. It can be the Product Serial as well. Woah, alright, sounds a bit extreme but whatever works : You could add it as an answer, maybe. Active Oldest Votes. Sign up or log in Sign up using Google.

Sign up using Facebook. Sign up using Email and Password. Post as a guest Name.



Comments

Akizshura

26.10.2020 at 10:12 pm

Ich bin Ihnen sehr dankbar. Riesige Danke.